Replacing your home’s electrical distribution board: a 2025 guide for Cádiz

Improve home safety (annual maintenance)

Having your installation checked once a year prevents faults, reduces electrical risks and extends the life of your equipment. At Inmatelec (Rota and the Bay of Cádiz) we carry out a technical inspection with certified measurements and provide a clear report with prioritised actions (critical / important / preventive).

What does our annual maintenance include?

  • Consumer unit
    • Visual inspection, cleaning and tightening of terminals.
    • Checking circuit labelling and DIN rail space for future additions (air conditioning, solar PV, EV).
    • Checking ratings and trip curves of miniature circuit breakers (PIAs).
  • Residual current devices (30 mA)
    • Testing with an instrument (trip time and current).
    • Verifying selectivity where there are several residual current devices (wet areas, kitchen, EV).
  • Surge protection devices (SPDs)
    • Checking status indicators (T1/T2 and permanent indicators).
    • Coordination with the other protective devices and a replacement recommendation where appropriate.
  • Earthing and continuity
    • Measuring earth resistance.
    • Verifying the continuity of protective conductors (PE).
  • Circuit insulation
    • Measurements between live / neutral / earth to detect leakage or insulation deterioration.
  • Thermography at critical points
    • Detecting abnormal overheating in circuit breakers, busbars, terminals and high-load connections.
  • Socket outlets and lighting
    • Checking socket outlets, visible joints and outdoor/wet areas (IP rating and watertightness).
    • If you have emergency lighting, testing its operation and basic autonomy.
  • Special loads
    • Checking consumption and protective devices for the water heater, air conditioning, oven, hob and, if present, the charging point.

Benefits for your home

  • Safety: reduces the risk of short circuits, overheating and indirect contact.
  • Savings: preventing a serious fault is much cheaper than repairing it.
  • Reliability: equipment protected against surges and unexpected tripping.
  • Preparation: distribution board ready for adding solar PV services or an EV charger without surprises.

Warning signs (request an inspection if you notice these)

  • Frequent tripping of the residual current device or any miniature circuit breaker.
  • Burning smell, covers or circuit breakers hot to the touch.
  • Flickering or dimming lights when high-power appliances are switched on (oven, air conditioning).
  • Red indicator on the SPD or blackened terminals/cables.

Your part: a mini monthly checklist (1 minute)

  • Press the TEST button on each residual current device: it should trip (switch it back on afterwards).
  • Check the SPD indicator: if it is red, let us know.
  • Check that there are no unusual smells, buzzing noises or overheating in the consumer unit.

Deliverables on completion

  • Technical report including:
    • Earthing values, insulation, RCD test results and relevant thermal images.
    • List of issues with priorities (critical / important / preventive) and an improvement plan.
  • Get a quote for remedial work (if required) and the recommended date for the next inspection.

Tip: Always leave DIN rail space free and keep the labelling up to date. This makes future extensions (air conditioning, PV, EV) easier and reduces intervention times.

CTA: Would you like your installation to be inspected and certified?? Schedule your annual maintenance with Inmatelec and receive a clear report with measurements and prioritised recommendations.

We use essential technologies to operate this website and remember your choices. Optional analytics will only be enabled with your permission. You can refuse them and continue browsing.

Cookie policy

Hola, soy Inma.

Asistente virtual de Inmatelec

Ir al formulario de contacto

No incluyas datos personales en el chat. El equipo revisará la viabilidad y el presupuesto.

WhatsApp